They’re typically placed at the top of the radiator because any air that will be trapped inside will be forced upwards by the pressurised water below. No, all radiator bleed valves are not the same size. Although many radiators use a standard size, you may find that designer radiators will have a different design. As you can see, this is not a difficult task and no need for panic stations. The best thing to do is keep calm and carry on. The article above is aimed at replacing standard bleed valves located on most radiators.

Our DECORATIVE range includes 8 different products with compression or push fit connections in 10mm and 15mm sizes This step is important to prevent leakage as new plugs alone will not be enough to prevent leakage so the threads will need to be wrapped with PTFE Tape. This is especially true when using new plugs on older radiators. The time to fix is either now or after this winter but before next winter. I'd go for the latter because I'd fit it in with work that's likely anyway then.Keep the valve open until the water stops flowing out although if you are unable to open the bleed valve, move on to step 4. Step 4 – Remove the Bleed Plug Make sure that you turn the heating off – the last thing you want is a trip to the hospital for scalding yourself!” Frequently Asked Questions Our unique range of TRVs includes TRV2, including a Petite version, remote sensor heads, TRV bodies, an attractive decorative model, as well a specially designed TRV kits to complement our LST radiator range. Note: If you were unable to open the bleed valve in step 3 – undo the plug slowly and be prepared for some water to escape. Step 5 – Wrap Your New Plugs with PTFE Tape

MYSON Controls produce a wide range of thermostatic radiator valves (TRVs) to suit any application, from standard domestic requirements to polished decorative products. Now you will need your adjustable spanner to remove the bleed plug (and the blank on the other end).

Registration for our free email newsletter.

The Unisenza Plus Receiver RF can be used for the wireless control of a boiler, pump, or zone valves in a central heating system. There are a number of reasons why you need or want to replace your bleed valve but don’t worry, it is not a difficult task so keep reading and we will cover that shortly. Leaks A leaking bleed valve can cause havoc in the pressurised system and will need rectifying sooner rather than later. You could try removing the bleed plug and attempting to reseal but, in most cases, it is best to just buy a new one. Aesthetics First, we need to turn off the heating system and let it cool. Inevitably there will be some water escaping when you replace the bleed valve, so it is best to make sure that the water is cold enough to touch. Step 2 – Isolate the Radiator in Question

You should be able to isolate an individual radiator with its own valves, with the caveat that some thermostatic valves leak a little when turned off especially if the room gets cold (mainly old ones but not necessarily). The balancing valve on the other end, which is almost always present, can be reset by counting turns as you close it then opening it the same amount. You'll get some water out, and it will be dirty, so protect the floor, walls etc. Bleed plugs can often be removed when a system needs draining or the radiator needs flushing and may be due to age, wear and tear or poor technique, you may end up struggling. How to Replace Radiator Bleed Valves

With most common radiator designs, at the top of each end, there will be a plug inserted – one of them will be blank (smooth finish) and the other will have some kind of opening or fitting that can be opened with a tool or key – this one is the bleed valve. Why do Radiator Bleed Valves Need Replacing? Personally, I know I need to drain, flush, descale, and refill, including inhibitor every couple of years anyway, because of a combination of hard water and the lowest point being a blower unit that easily clogs, in a room that needs the heat. Getting the sludge out of that is a good few hours' work; fixing this valve would be a minor addition to the effort. I'd one of each main type to have on hand, but consider it not guaranteed to fit so wouldn't remove the old one when the shops are shut. Products Another reason could be because the bleed valve has been painted over and doesn’t look very good and you want to have nice shiny fittings on your radiators. I'd be a little wary of relying on the outside nut long term in case of leaks developing. Most of my radiators need bleeding at this time of year, a couple of them more than once, so that might mean a few openings. New ones often have an o-ring seal which can tolerate opening, but older ones didn't.

After removing the plugs there will be a bit of air in the system that should make it to the AAV although now would be a good time to make sure all of the radiators are bled. Conclusion If you have had to remove the bleed plug for any reason, you may be struggling to get a good and watertight seal. One of the most common reasons for replacing a bleed valve is that the bleed valve has failed and is leaking. The MYSON TRV2 range includes over 20 different products with compression or push fit connections in 10mm, 15mm and ½” sizesNow you will need to clean around openings, insert the plugs and do them up nice and tight letting the PTFE tape create the seal. Step 6 – Turn on the System TRVs are one of the most efficient ways of controlling the heat in your home and by installing TRVs you could save up to 40% on heating bills, as independently tested by the University of Salford.When set at the correct level they will keep the room at the desired temperature.As they are installed on each radiator, you can have different settings in each room and they can be turned off in rooms that aren’t been used.