276°
Posted 20 hours ago

APC - AP9641 - UPS Network Management Card with Network Shutdown and Environmental Monitoring

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

NOTE:To upgrade multiple Management Cards using an FTP client or using SCP, write a script which automatically performs the procedure. Connect the provided serial configuration cable (APC part number 940-0299) to the selected2.5mm Tip-Ring-Sleeve Consoleporton the Management Card itself. First it requires an NMC3 (which all soon will require a subscription). Fine. I got one. But oddly enough it cannot browse for a SSID, you have to manually enter one and then be smart enough to know what flavor of WPA2 your router uses (there are three options). Worse yet when you activate the wireless adapter the Ethernet port on your NMC3 is disabled. NOTE: Network Management Cards with theSKU of AP9617, AP9618, or AP9619 use firmware 3.X and Network Management Card 2 units with theSKU of AP9630, AP9631 use version 5.X or 6.X firmware. The correct firmware for each platform must be used and they are not interchangeable.

You then need to change the terminal program's baud rate to match the one you selected in step 12. If you are using HyperTerminal select Call ->Disconnect and go to File->Properties->Configure and choose the correct speed.Accept the changes and then to reestablish the connectionchoose theCall menu->Connect to apply changes made to the serial port. Press to continue.From the terminal program's Transfer menu, select the appropriate firmware .bin firmwarefile to transfer via XMODEM-CRC. To do this within HyperTerminal, go to Transfer ->Send File. On the dialog box that pops up, browse the computer for the appropriate firmware .bin file. Once you do that, ensure the selected protocol is XMODEM and then press Send to begin the file transfer. For AP9617/18/19 based devices, the AOS should be transferred first and then the procedure should be repeated for the application file. Devices with an embedded Web/SNMP Card include (but are not limited to): Environmental Monitoring Unit 1 (AP9312TH)

Trading In Multiple UPSs: Customers can trade in multiple UPSs for larger UPSs. The VA of the multiple units can be combined, then doubled, to get a maximum VA the customer is eligible to trade up to. Customer cannot trade in UPSs for any single or multiple UPSs of lesser value (VA) than the combined VA of all units traded in. Typically, these upgrades do not require the device the NetworkManagement Card is installed in to be powered down or cause unnecessary downtime.

Create a Support Ticket

NOTE: To upgrade multiple Management Cards using an FTP client or using SCP, write a script which automatically performs the procedure. This feature is available in bootloader version v1.3.3.1 and higher. Before starting the transfer, make sure the USB drive is formatted in FAT, FAT16 or FAT32. Ships with AP9630 pre-installed in units manufactured post 2012. Older G7000 models require a special upgrade kit pre-2012 manufacture date. NOTE: If the boot monitor module must be updated, a boot monitor module is included in the firmware release. Otherwise, the boot monitor module that is installed on the card is compatible with the firmware update. Ifthere is no included bootmonitor file, upgrade theAOS binaryfirst.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment