Probably it would need connecting to the wiring centre, not to the controller as you have with the TP9000. HOWEVER. We can offer you an alternative model that WILL FIT the FP715SIwithout an Electrician and without paying through the NOSE. This is what this listing is Selling - please get in touch if you are unsure

User manual Danfoss FP715Si (English - 24 pages)

There is a 230 volt and 24 volt model it seems, this is the instructions. https://www.plumbase.co.uk/link/1/h002877_20563_t.pdf If however as likely it switches 230 volt, then you can fit a system which can link to TRV's in the future allowing you to control each room independently. One of the key features of the FP715Si is its multiple switching options. This thermostat can control both the heating and hot water systems, providing convenience and flexibility. This allows users to manage their overall energy consumption effectively.

The item was delivered before the deadline date in good condition . Delivery option was the best I found for the single item. Earth, neutral and live is fairly self-explanatory. Am I correct in thinking that the following applies? But can I bypass the wiring of the danfoss to just make the CH on all the time, so it can then be left switched off on the danfoss? Or does that confuse it?!

Danfoss FP715SI 7 Day 24 Hour Or 5/2 Day Programmer

But the Hive is much simpler and cheaper, no option for Opentherm, and no cleaver algorithms, and the base stops taking a demand for heat after 22ºC so the base unit really designed to be in a room normally kept cool, like the hall. Although your likely not considering swapping all TRV heads to linked heads now, before selecting a replacement you need to consider what you may want to do in the future. The terminals used will depend on the design of plumbing system that it is controlling. Yours is commensurate with very many in the UK. Some do have a connection to terminal 1 others, like yours don't need it. None, (with a few very rare exceptions, normally old installations) have a connection to terminal 2.The Danfoss FP720 (replacing the FP715Si) two-channel full programmer has separate heating and hot water outputs operating on completely independent time bases for maximum flexibility. I got it wrong, so trying to stop you making same mistake, I selected Energenie as was told they worked with Nest, but that is not the case. There is a guide here which also says Energenie works with Nest, seems they did until Google took them over. Discovered during the night that the central heating was still on despite the programmer indicator light being off. Turned the thermostat right down but heating stayed on. Time for a new programmer. An additional range of accessories allow the FP715 Si to be used in other upgrade situations where the unit being replaced is larger than the new unit and a decoration scar would normally have been left. I was hoping to be able to do this myself, as I like to learn new skills, but it sounds like this would be a step outside my comfort zone

Danfoss FP715SI Programmer (Discontinued Product from Danfoss Danfoss FP715SI Programmer (Discontinued Product from Danfoss

As it works with just one thing on at once in my case, is it possible to bridge the wires for the Central Heating so that it is in effect on all the time but could be left in the off position? Relieved to see that this programmer is still available but thanks to coronavirus getting a tradesman to fit one could be a problem as we are in isolation due to age. The FP715Si features a user-friendly interface and a clear digital display, making it simple to program and operate. With its intuitive navigation, users can easily set up specific heating schedules and temperature levels for different times of the day. The FP715 Si two-channel full programmer has separate Heating and Hot Water outputs operating on completely independent time bases for maximum flexibility. So I'm not sure if the programmer is just duff, or if there is a certain combination of events which is causing the programmer to trip out.I guess I will just plump for the 2 channel controller that I like best and hire a sparky to install it (I know my limitations).